Barry D.E.W. Line® Dielectric Tag Line

Product Code: HL-NK1000

Insulating rope tool offering excellent dielectric properties and designed for performing live work on AC or DC energized apparatus.

Meets or exceeds the dry or wet electrical requirements of :

  • IEC 62192:2009
  • ASTM F1701-12
IEC 62192:2009 - Average dry and wet test results
IEC 62192:2009 Dry 1 min Wet 1 min Wet 5 min
HL-NK1000 Pass (~ 87 µA) Pass (~ 18 µA) Pass (~ 18 µA)

Note: Test with no shielding of capacitive currents.


ASTM F1701-12 - Average dry and wet test results
ASTM F1701-12 Dry Wet
HL-NK1000 Pass (~ 3 µA) Pass (~ 3 µA)

Note: Test with shielding of capacitive currents.

 

Arc-Flash rated

  • Resistant to 40 cal/cm2 (category 4)

Features

  • Unique insulating properties
  • Cleanable and easy to maintain and test
  • Exceptionally low leakage current, whether dry or wet
  • Protection from high fault current
  • High strength
  • Low elongation
  • Lightweight and low volume
  • Fully sealed and hydrophobic
  • Smooth surface
  • High abrasion resistance
  • Easy to deploy
  • Excellent resistance to UV
  • High visibility sealed termination at each end
  • Comes with transport bag

SPECIFICATIONS

  • Working Load Limit: 200 lb (90 kg)
  • Diameter: 1/4” (6 mm)
  • Terminations: Stainless steel thimble at each end
  • Colour: Black with bright orange terminations
  • Weight:78 lb (0.35 kg) for 20’ length
  • Standard Lengths: 20’ (6.1 m), 30’ (9.1 m), 40’ (12.2 m)

Note: Available in other lengths. Contact Barry for more information.